Unit of Measure

Voltage

N/A 208/230 V

Frequency

N/A 60 Hz

Number of Phases

N/A 3

Outdoor Sound Rating

N/A 80 dB

Refrigerant Charge

N/A 112 oz3175.1 g

Minimum Circuit Ampacity

N/A 23

Minimum Overcurrent Protection Device Size

N/A 30

Maximum Overcurrent Protection Device Size

N/A 30

Shipping Weight

N/A 520 lb236 kg

Weight

N/A 231 kg510 lb

Nominal Cooling Capacity

N/A 48000 Btu/h14.07 kW

EER2

N/A 11.5

SEER2

N/A 15.2

Nominal CFM

N/A 1600 ft³/min755 L/s

AHRI Rated CFM

N/A 1430 ft³/min675 L/s

AHRI Net Cooling Capacity

N/A 45500 Btu/h13.34 kW

Net Sensible Cooling Capacity

N/A 34200 Btu/h10.02 kW

Net Latent Cooling Capacity

N/A 11300 Btu/h3.31 kW

Net System Power

N/A 3.96 kW

High Temp. Rating

N/A 45500 Btu/h13.34 kW

High Temp. Rating - System Power

N/A 3.65 kW

High Temp. Rating - System Power - COP

N/A 3.65

Low Temp. Rating

N/A 24600 Btu/h7.21 kW

Low Temp. Rating - System Power

N/A 3.11 kW

Low Temp. Rating - System Power - COP

N/A 2.32

HSPF2

N/A 7.2

Heating Input (1st Stage / 2nd Stage)

N/A 70000 / 100000 Btu/h20.51 / 29.30 kW

Heating Output (1st Stage / 2nd Stage)

N/A 56700 / 81000 Btu/h16.62 / 23.74 kW

Steady State Efficiency

N/A 81 %

No. Burners

N/A 5

No. Stages

N/A 2

Gas Connection Pipe Size

N/A 1/2 in12.70 mm

Type

N/A Scroll

No. Stages

N/A 2

Fin Type

N/A MicroChannel

Tube Type

N/A MicroChannel

MicroChannel Depth

N/A 1.00 in25.4 mm

Face Area

N/A 16.29 ft²1.51 m²

Rows

N/A 1

FPI

N/A 16

Fin Type

N/A MicroChannel

Tube Type

N/A MicroChannel

MicroChannel Depth

N/A 1 in25.4 mm

Face Area

N/A 7.6 ft²0.71 m²

Rows

N/A 1

FPI

N/A 20

Refrigerant Control

N/A TXV

Drain Connection No.

N/A 1

Drain Connection Size

N/A 0.75 in19.05 mm

Type

N/A Propeller

No. Used

N/A 1

Diameter

N/A 24 in609.6 mm

Drive Type

N/A Direct

CFM

N/A 4100 ft³/min1935 L/s

No. Motors

N/A 1

Horsepower

N/A 1/3 hp

Motor RPM

N/A 825

Type

N/A Constant CFM

No. Used

N/A 1

Diameter

N/A 11x9 in279x229 mm

Drive Type

N/A Direct

No. Speeds

N/A Variable Speed

No. Motors

N/A 1

Motor HP

N/A 1 hp

Motor RPM

N/A 1300

Type

N/A Field Supplied

Furnished

N/A No

No. Filters

N/A 2

Recommended Size

N/A 1x16x30 in25x406x762 mm

Depth

N/A 46 11/18 in

Width

N/A 55 25/32 in

Height

N/A 41 in

N/A

  • Two-Stage Scroll Compressors on all Models: Modulates between two capacity settings — 67% and 100% — providing more precise temperature control, lower humidity and greater efficiency in comparison to single stage compressors. It uses 70% fewer moving parts which also increases efficiency and reliability
  • Two-Stage Northern Heat Pump Configuration (Two-Stage HP Heat/Single-Stage Cool) 2 Ton Only: Provides 40% higher heating capacity than a standard heat pump. Leaving air temperature is an average of 5 degrees warmer at all heating conditions, than standard single or two stage heat pumps
  • PlusOne® Diagnostics1: The Rheem Contractor App and built-in EcoNet® & Bluetooth®2 technology, makes monitoring, troubleshooting and repairing the product easier than ever before
  • Installation Commissioning via Bluetooth® Technology: Seamless final install step without DIP switch configuration using the Rheem Contractor App.
  • On-demand Dehumidification: Available through EcoNet® thermostat
  • MicroChannel Evaporator and Condenser Coil: Delivers superior performance with less refrigerant charge and less weight than conventional copper tube/aluminum fin coils. All aluminum construction has superior protection against formicary corrosion and aluminum tube rubbing potential. It is easier to clean and has a more robust surface
  • Constant Volume Motor: Truly variable speed technology allows for ultimate humidity control, quieter sound levels and year-round energy savings
  • Dedicated Heating Speeds: Maintain consistent performance via Constant CFM motor to keep temp rise at a comfortable level
  • Thermal Expansion Valves: Standard on all models for precise superheat control, reliability, and energy efficiency at all operating conditions
  • High and Low Pressure Control: Standard on all models for refrigerant component protection and reliability
  • Filter Drier: Standard on all models
  • 100% Factory Run Tested
  • Stainless Steel Heat Exchanger: Available as factory installed option for better corrosion resistance
  • PlusOne® Ignition System: Proven Direct Spark Ignition System (DSI) for reliability and longevity
  • PlusOne® Refrigerant Detection System™: An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation – if excess refrigerant is detected
  • Rugged Base Rail: For improved installation and handling.
  • Easily Accessible Control Box, Furnace Compartment and Slide-Out Blower Section: Allows for installability and serviceability
  • Side and Down Discharge Options Available: All models are shipped ready for horizontal applications
  • Double Sloped Evaporator Coil Drain Pan: Allows for complete water removal from the unit—contributing to improved indoor air quality
  • Louvered Condenser Compartment: Protects the coil against yard hazards and/or weather extremes
  • Supply and Return Air Openings: Feature a one-inch-tall flange to prevent water migration into the ductwork
  • Designing for Sustainability with Low GWP: For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems. This new requirement will result in a 78%3 lower GWP than previous-generation refrigerants with only minimal changes to system installation. For us, this another step toward our continued sustainability goal of reducing greenhouse gas emissions, while still delivering an exceptional level if energy efficient, dependable comfort

1Bluetooth functionality applies to the heating section only.
2The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Rheem® is under license. Other trademarks and trade names are those of their respective owners.
3When comparing the GWP of R-454B to R-410A refrigerant.

©Rheem Manufacturing Company. Rheem trademarks owned by Rheem Manufacturing Company.