  • Cooling Efficiency: 15.2 SEER2/11.5 EER2
  • Refrigerant Type: R-454B
  • Nominal Sizes 2 to 5 Tons [7.0 – 17.6 kW]
  • Rated Cooling Capacities: 22.8 to 56 kBTU
  • EcoNet® Enabled: No
  • Compressor Type: Two-Stage Scroll
  • Evaporator Coil Type: MicroChannel
  • Condenser Coil Type: MicroChannel
  • Airflow Type: Convertible
  • Ultra Low NOx Option: No
  • Low NOx Option: No
  • 1-Phase Option: Yes
  • 3-Phase Option: Yes
  • Compatible Thermostat: Single-Stage 24V
  • PlusOnes:
    • PlusOne® Refrigerant Detection System™1- Integrated, patented design providing system protection and homeowner peace-of-mind with low GWP refrigerant monitoring

1Factory installed on 3.5, 4 and 5 ton models. For R-454B equipment with a refrigerant charge less than 3.9 lbs (≈1.8 kg or ≈62.6 oz), a refrigerant detection system is not required by the UL 60335-2-40 standard.

Unit of Measure

Voltage

N/A 460 V

Frequency

N/A 60 Hz

Number of Phases

N/A 3

Outdoor Sound Rating

N/A 81 dB

Refrigerant Charge

N/A 81 oz2296 g

Minimum Circuit Ampacity

N/A 13

Minimum Overcurrent Protection Device Size

N/A 15

Maximum Overcurrent Protection Device Size

N/A 15

Shipping Weight

N/A 465 lb211 kg

Weight

N/A 206 kg455 lb

Nominal Cooling Capacity

N/A 48500 Btu/h14.21 kW

EER2

N/A 12

SEER2

N/A 16

Nominal CFM

N/A 1600 ft³/min755 L/s

AHRI Rated CFM

N/A 1525 ft³/min720 L/s

AHRI Net Cooling Capacity

N/A 45500 Btu/h13.33 kW

Net Sensible Cooling Capacity

N/A 33300 Btu/h9.76 kW

Net Latent Cooling Capacity

N/A 14200 Btu/h4.16 kW

Net System Power

N/A 3.84 kW

Type

N/A Double-Stage Scroll

No. Stages

N/A 1

Fin Type

N/A Louvered

Tube Type

N/A MicroChannel

MicroChannel Depth

N/A 1 in25.4 mm

Face Area

N/A 15.98 ft²1.48 m²

Rows

N/A 1

FPI

N/A 23

Fin Type

N/A Louvered

Tube Type

N/A MicroChannel

MicroChannel Depth

N/A 1 in25.4 mm

Face Area

N/A 7.07 ft²0.66 m²

Rows

N/A 1

FPI

N/A 20

Refrigerant Control

N/A TX Valves

Drain Connection No.

N/A 1

Drain Connection Size

N/A 0.75 in19.05 mm

Type

N/A Propeller

No. Used

N/A 1

Diameter

N/A 24 in609.6 mm

Drive Type

N/A Direct

No. Speeds

N/A 1

CFM

N/A 4300 ft³/min2029 L/s

No. Motors

N/A 1

Horsepower

N/A 1/3 hp

Motor RPM

N/A 1050

Type

N/A FC Centrifugal

No. Used

N/A 1

Diameter

N/A 12x9 in305x229 mm

Drive Type

N/A Direct

No. Speeds

N/A Multiple

No. Motors

N/A 1

Motor RPM

N/A 1050

Motor Frame Size

N/A 48

Type

N/A Field Supplied

Furnished

N/A No

No. Filters

N/A 2

Recommended Size

N/A 1x16x30 in25x406x762 mm

Depth

N/A 46 11/18 in

Width

N/A 55 25/32 in

Height

N/A 41 in

N/A

  • Two-Stage Scroll Compressors on all models: Modulates between two capacity settings — 67% and 100% — providing more precise temperature control, lower humidity and greater efficiency in comparison to single stage compressors. It uses 70% fewer moving parts which also increases efficiency and reliability
  • PlusOne® Diagnostics1: The Rheem Contractor App and built-in EcoNet® & Bluetooth®2 Technolog, makes monitoring, troubleshooting and repairing the product easier than ever before
  • Installation Commissioning via Bluetooth® Technology: Seamless final install step without DIP switch configuration using the Rheem Contractor App.
  • On-demand dehumidification: Available through EcoNet® thermostat superior performance with less refrigerant charge and less weight than conventional copper tube/aluminum fin coils. All aluminum construction has superior protection against formicary corrosion and aluminum tube rubbing potential. It is easier to clean and has a more robust surface.
  • Constant CFM Motor: Truly variable speed technology allows for ultimate humidity control, quieter sound levels and yearround energy savings
  • Dedicated heating speeds: Maintain consistent performance via Constant CFM motor to keep temp rise at a comfortable level
  • Thermal Expansion Valves: Standard on all models for precise superheat control, reliability, and energy efficiency at all operating conditions
  • High and low Pressure Control: Standard on all models for refrigerant component protection and reliability
  • Filter Drier: Standard on all models
  • 100% Factory Run Tested
  • Stainless Steel Heat Exchanger: Available as factory installed option for better corrosion resistance
  • PlusOne® Ignition System: Proven Direct Spark Ignition System (DSI) for reliability and longevity
  • PlusOne® Refrigerant Detection System™3: An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation – if excess refrigerant is detected
  • Rugged Base Rail: For improved installation and handling. Easily Accessible Control Box, Furnace Compartment and Slide-Out Blower Section: Allows for installability and serviceability
  • Side and Down Discharge Options Available: All models are shipped ready for horizontal applications
  • Double Sloped Evaporator Coil Drain Pan: Allows for complete water removal from the unit—contributing to improved indoor air quality
  • Louvered Condenser Compartment: Protects the coil against yard hazards and/or weather extremes
  • Supply and Return Air Openings: Feature a one-inch-tall flange to prevent water migration into the ductwork
  • Designing for Sustainability with Low GWP: For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems. This new requirement will result in a 78%4 lower GWP than previous-generation refrigerants with only minimal changes to system installation. For us, this is another step toward our continued sustainability goal of reducing greenhouse gas emissions, while still delivering an exceptional level if energy efficient, dependable comfort

1Bluetooth functionality applies to the heating section only. 2The BluetoothR word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by RheemR is under license. Other trademarks and trade names are those of their respective owners. 3Factory installed on 3.5, 4 and 5 ton models. For R-454B equipment with a refrigerant charge less than 3.9 lbs (≈1.8 kg or ≈62.6 oz), a refrigerant detection system is not required by the UL 60335-2-40 standard. 4When comparing the GWP of R-454B to R-410A refrigerant.

©Rheem Manufacturing Company. Rheem trademarks owned by Rheem Manufacturing Company.