  • Scroll Compressors on all models: Provides maximum efficiency and quiet operation.
  • Thermal Expansion Valves: Standard on all models for precise superheat control, reliability, and energy efficiency at all operating conditions.
  • High Pressure Control / Low Press Control Standard on all models for refrigerant component protection and reliability.
  • Easily Accessible Control Box and Slide-Out Blower Section Allows for faster installability and serviceability.
  • Supplemental Electric Heating Option Available: Field-Installed, electrical heat strips, up to 15 kW with simplified single-point wiring, are available for periods of extreme weather conditions.
  • Tested. Trusted. Tough. 100% Factory Run Tested.
  • PlusOne® Refrigerant Detection System™>1 Integrated, patented design providing system protection and homeowner peace-of-mind with low GWP refrigerant monitoring

1 Factory installed. For R-454B equipment with a refrigerant charge less than 3.9 lbs (≈1.8 kg or ≈62.6 oz), a refrigerant detection system is not required by the UL 60335-2-40 standard.

Unit of Measure

Voltage

N/A 208/230 V

Frequency

N/A 60 Hz

Number of Phases

N/A 3

Sound Level

N/A 79 dB

Refrigerant Charge

N/A 206.2 g5846 oz

Minimum Circuit Ampacity

N/A 30

Minimum Overcurrent Protection

N/A 35

Maximum Overcurrent Protection

N/A 45

Shipping Weight

N/A 454 lb206 kg

Weight

N/A 429 lb195 kg

Nominal Cooling Capacity

N/A 60000 Btu17.58 kW

EER2

N/A 10.6

SEER2

N/A 13.4

Nominal CFM

N/A 1906 ft³/min900 L/s

AHRI Rated CFM

N/A 1900 ft³/min897 L/s

AHRI Net Cooling Capacity

N/A 57000 Btu16.7 kW

Net Sensible Capacity

N/A 40210 Btu11.78 kW

Net Latent Capacity

N/A 16790 Btu4.92 kW

Net System Power

N/A 5.38 kW

High Temp. Rating

N/A 56400 Btu16.53 kW

High Temp. Rating - System Power

N/A 3.41 kW

Low Temp. Rating

N/A 31400 Btu/hr9.2 kW

Low Temp. Rating - System Power

N/A 2.14 kW

HSPF2

N/A 6.7

Compressor Type

N/A Single-Stage Scroll

Fin Type

N/A Louvered

Tube Type

N/A Rifled

MicroChannel Depth

N/A 0.375 in9.53 mm

Face Area

N/A 32.39 ft²3.01 m²

Rows

N/A 2

FPI

N/A 18

Fin Type

N/A Louvered

Tube Type

N/A Rifled

MicroChannel Depth

N/A 0.375 in9.53 mm

Face Area

N/A 5.8 ft²0.54 m²

Rows

N/A 4

FPI

N/A 13

Refrigerant Control

N/A TX Valves

Drain Connection No.

N/A 1

Drain Connection Size

N/A 1 in25.40 mm

Type

N/A Propeller

No. Used

N/A 1

Diameter

N/A 24 in609.6 mm

Drive Type

N/A Direct

No. Speeds

N/A 1

CFM

N/A 4500 ft³/min2124 L/s

No. Motors

N/A 1

Horsepower

N/A 1/2 hp

Motor RPM

N/A 1075

Type

N/A FC Centrifugal

No. Used

N/A 1

Diameter

N/A 11x9 in279x229 mm

Drive Type

N/A Direct

No. Speeds

N/A Multiple

No. Motors

N/A 1

Horsepower

N/A 1 hp

Motor RPM

N/A 1050

Motor Frame Size

N/A 48

Type

N/A Field Supplied

Furnished

N/A No

No. Filters

N/A 1

Recommended Size

N/A 1x24x24 in25x610x610 mm

Depth

N/A 33 in

Width

N/A 59 in

Height

N/A 37 1/8 in

N/A

  • Scroll Compressors on all models: Provides maximum efficiency and quiet operation
  • Two Thermal Expansion Valves: One for cooling, one for heating and are standard on all models for precise superheat control, reliability, and energy efficiency at all operating conditions
  • High and Low Pressure Controls: Standard on all models for refrigerant component protection and reliability
  • Filter Drier: Standard on all models
  • 100% Factory Run Tested
  • PlusOne® Refrigerant Detection System™: An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation – if excess refrigerant is detected
  • Metal Base Rails: Allow for separation between the unit base and the ground level, protecting the base from ground moisture and providing air circulation around the unit. It also allows for easier maneuverability during installation. To provide flexibility in space limited installations, the unit can be installed flush to the structure without blocking airflow over the outdoor coil or making any screws inaccessible for maintenance
  • Two Round 14" Duct Collars: Included with each unit. The collar is crimped around the leading edge, making it easier to install duct onto the collar. A metal bead around the circumference prevents the attached ducting form sliding off after installation
  • Easy High and Low Refrigerant Pressure Measurement: Two gauge ports located inside the control box allow for ease and accuracy
  • Removable Sloped Drain Pan: Accessible through a small side panel. Helps to ensure indoor air quality (IAQ) throughout the life of the unit
  • Closed-Cell Insulation: Used on the base of the unit, to prevent moisture from being absorbed and helps reduce mold content
  • Louvered Condenser Compartment: Protects the coil against yard hazards and/or weather extremes
  • Easy Accessible Controls:
    — Located in a large control box providing plenty of space for troubleshooting
    — Demand defrost control is used to manage the defrost cycle
    — Transformer is protected by an in-line fuse, which protects the transformer during a low-voltage electrical short
    — Low-voltage and high-voltage wiring connections are easily accessed and have ample room to maneuver
    — Number and color-coded wiring aids in troubleshooting and corresponds with the large, easy-to-read wiring diagram located on the inside of the control box access panel
  • Easily Removable Outdoor and Indoor Section Top Cover: Allows access to the compressor, refrigerant tubing, blower housing and motors for easy required cleaning and service
  • Factory and Field Installed Supplemental Electric Heat Strips: Available for periods of extreme cold temperatures with either dual or single-point power
  • Designing for Sustainability with Low GWP: For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems. This new requirement will result in a 78%1 lower GWP than previous-generation refrigerants with only minimal changes to system installation. For us, this is another step toward our continued sustainability goal of reducing greenhouse gas emissions, while still delivering an exceptional level if energy efficient, dependable comfort