• R-410A HFC refrigerant.
  • Complete factory charged, wired and run tested.
  • Scroll compressors with internal line break overload and high-pressure protection.
  • Single stage compressor on all models (except RKQN-A060 two stage Ultra Tech).
  • Convertible airflow.
  • TXV refrigerant metering system on each circuit.
  • High Pressure and Low Pressure/Loss of charge protection standard on all models.
  • Solid Core liquid line filter drier on each circuit.
  • Single slab, Micro Channel designed evaporator coil facilitate easy cleaning for maintained high efficiencies.
  • Cooling operation up to 125 degree F ambient.
  • Easily removable filter, blower, gas heat, and compressor/ control access panels permits prompt service.
  • One piece top cover and one piece base pan with drawn supply and return opening for superior water management.
  • Externally mounted refrigerant gauge ports for easy service diagnostics.
  • Easy to install plug-in; slip in, 100% fully modulating economizer.
  • Forkable base rails for easy handling and lifting.
  • Single point electrical and gas connections.
  • Direct drive or high performance belt drive motor with variable pitch pulleys and quick adjust belt system.
  • Permanently lubricated evaporator, condenser and gas heat inducer motors.
  • Condenser motors are internally protected, totally enclosed with shaft down design.
  • 1 inch filter standard with slide out design. Will accept 2 inch filter.
  • Single stage gas valve, direct spark ignition, and induced draft for efficiency and reliability.
  • Improved Gas Heating Efficiency (AFUE: 81%).
  • Tubular heat exchange for long life and induced draft for efficiency and reliability.
  • Solid state furnace control with on board diagnostics.
  • Colored and labeled wiring.
  • Molded compressor plug.
  • Through the base gas and electric.
  • Micro Channel evaporators and condenser delivers superior performance with less refrigerant charge and less weight than conventional copper tube/aluminum fin coils. In addition the all aluminum design has superior formicary corrosion protection and less potential for leaks due to elimination of tube rubbing potential. Its easier to clean and has a more robust surface.
26 - 45 of 45 | Results Per Page | View | Unit of Measure
1 2 

Item #

Gross Cooling Capacity

Nominal CFM

AHRI Rated CFM

Weight

N/A 48000 Btu N/A 1600 ft³/min N/A 1600 ft³/min N/A 543 lb
N/A 48000 Btu N/A 1600 ft³/min N/A 1600 ft³/min N/A 551 lb
N/A 48000 Btu N/A 1600 ft³/min N/A 1600 ft³/min N/A 556 lb
N/A 48000 Btu N/A 1600 ft³/min N/A 1600 ft³/min N/A 561 lb
N/A 48000 Btu N/A 1600 ft³/min N/A 1600 ft³/min N/A 552 lb
N/A 48000 Btu N/A 1600 ft³/min N/A 1600 ft³/min N/A 557 lb
N/A 48000 Btu N/A 1600 ft³/min N/A 1600 ft³/min N/A 562 lb
N/A 48000 Btu N/A 1600 ft³/min N/A 1600 ft³/min N/A 533 lb
N/A 48000 Btu N/A 1600 ft³/min N/A 1600 ft³/min N/A 538 lb
N/A 48000 Btu N/A 1600 ft³/min N/A 1600 ft³/min N/A 543 lb
N/A 59000 Btu N/A N/A 1375 ft³/min1800 ft³/min N/A 548 lb
N/A 59000 Btu N/A N/A 1375 ft³/min1800 ft³/min N/A 555 lb
N/A 59000 Btu N/A N/A 1375 ft³/min1800 ft³/min N/A 548 lb
N/A 59000 Btu N/A N/A 1375 ft³/min1800 ft³/min N/A 555 lb
N/A 59000 Btu N/A N/A 1375 ft³/min1800 ft³/min N/A 548 lb
N/A 59000 Btu N/A N/A 1375 ft³/min1800 ft³/min N/A 555 lb
N/A 59000 Btu N/A N/A 1375 ft³/min1800 ft³/min N/A 604 lb
N/A 59000 Btu N/A N/A 1375 ft³/min1800 ft³/min N/A 611 lb
N/A 59000 Btu N/A N/A 1375 ft³/min1800 ft³/min N/A 548 lb
N/A 59000 Btu N/A N/A 1375 ft³/min1800 ft³/min N/A 555 lb
26 - 45 of 45 | Results Per Page | View | Unit of Measure
1 2