Rheem Logo Background

CAD/BIM

  • RP14AY

    • Cooling & Heating Efficiency: 15.2 SEER2/11.7 EER2/7.8 HSPF2
    • Refrigerant Type: R-454B
    • Nominal Sizes: 1.5 to 5 Tons [TBD kW]
    • Cooling & Heating Capacities: 17.1 to 54 kBTU
    • Sound Ranking1: As low as 72 dB
    • ENERGY STAR® Certified3: Yes
    • EcoNet® Enabled: No
    • Compressor Type2: Two-Stage
    • Condenser Coil Type: 7mm
    • PlusOnes:
      • PlusOne® Expanded Valve Space: Provides a minimum working area of 27-sqaure inches
      • PlusOne Triple Service Access : 15 in. wide industry leading corner service access, two fastener removeable corner and easily removeable individual louver panels
      • PlusOne® Refrigerant Detection System™4: Integrated, patented design providing system protection and homeowner peace-of-mind with low GWP refrigerant monitoring
    • Limited Warranty*: Conditional Parts: 10 Years (registration required)

    *For complete details of the limited and conditional warranties, including applicable terms and conditions, contact your local Contractor or go to Rheem.com for a copy of the product warranty certificate.
    1Based on Internal R&D Testing, May 2022. Sound levels are also dependent on proper installation and location of outdoor product.
    2The 1.5 ton model features a single-stage compressor.
    3Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR. Ask your contractor for details or visit EnergyStar.gov.
    4Factory or field installed in the furnace coil or air handler and is applicable to the complete heating and cooling system featuring Low GWP Refrigerant (A2L).

  • WP15AY

    • Cooling & Heating Efficiency: 15.2 SEER2/11.7 EER2/7.8 HSPF2
    • Refrigerant Type: R-454B
    • Nominal Sizes: 1.5 to 5 Tons [TBD kW]
    • Cooling & Heating Capacities: 17.1 to 54 kBTU
    • Sound Ranking2: As low as 73 dB
    • EcoNet® Enabled: No
    • ENERGY STAR® certified3: Yes
    • Compressor Type: Two-Stage
    • Condenser Coil Type: 7mm
    • Features:
    • Expanded Valve Space: Provides a minimum working area of 27-sqaure inches
    • Refrigerant Detection System™4- Integrated, patented design providing system protection and homeowner peace-of-mind with low GWP refrigerant monitoring
    • Limited Warranty1: Conditional Compressor: 10 Years (registration required) Parts: 5 Years

    1For complete details of the limited and conditional warranties, including applicable terms and conditions, contact your local Contractor or go to Rheem.com for a copy of the product warranty certificate.
    2Based on Internal R&D Testing, May 2022. Sound levels are also dependent on proper installation and location of outdoor product.
    3Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR. Ask your contractor for details or visit EnergyStar.gov.
    4Factory or field installed in the furnace coil or air handler and is applicable to the complete heating and cooling system featuring Low GWP Refrigerant (A2L).

  • WP14AY

    • Cooling & Heating Efficiency: 15.2 SEER2/11.7 EER2/7.8 HSPF2
    • Refrigerant Type: R-454B
    • Nominal Sizes: 1.5 to 5 Tons [TBD kW]
    • Cooling & Heating Capacities: 17.1 to 54 kBTU
    • Sound Ranking1: As low as 72 dB
    • ENERGY STAR® Certified2: Yes
    • EcoNet® Enabled: No
    • Compressor Type3: Two-Stage
    • Condenser Coil Type: 7mm
    • Features: Expanded Valve Space: Provides a minimum working area of 27-sqaure inches
      Refrigerant Detection System™4: Integrated, patented design providing system protection and homeowner peace-of-mind with low GWP refrigerant monitoring
    • Limited Warranty*:
      Parts: 5 Years
      Conditional Compressor: 10 Years (registration required)

    *For complete details of the limited and conditional warranties, including applicable terms and conditions, contact your local Contractor or go to Rheem.com for a copy of the product warranty certificate.
    1Based on Internal R&D Testing, May 2022. Sound levels are also dependent on proper installation and location of outdoor product.
    2Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR. Ask your contractor for details or visit EnergyStar.gov.
    3The 1.5 ton model features a single-stage compressor.
    4Factory or field installed in the furnace coil or air handler and is applicable to the complete heating and cooling system featuring Low GWP Refrigerant (A2L).

  • RP15AY

    • Cooling & Heating Efficiency: 16 SEER2/11.7 EER2/8.1 HSPF2
    • Refrigerant Type: R-454B
    • Nominal Sizes: 1.5 to 5 Tons [TBD kW]
    • Cooling & Heating Capacities: 17.1 to 55.5 kBTU
    • Sound Ranking2: As low as 73 dB
    • EcoNet® Enabled: No
    • ENERGY STAR® certified3: Yes
    • Compressor Type: Two-Stage
    • Condenser Coil Type: 7mm
    • PlusOnes:
      • PlusOne® Expanded Valve Space: Provides a minimum working area of 27-sqaure inches
      • PlusOne Triple Service Access – 15 in. wide industry leading corner service access, two
      • fastener removeable corner and easily removeable individual louver panels
      • PlusOne® Refrigerant Detection SystemTM4- Integrated, patented design providing system
      • protection and homeowner peace-of-mind with low GWP refrigerant monitoring
    • Limited Warranty1: Conditional Parts: 10 Years (registration required)

    1For complete details of the limited and conditional warranties, including applicable terms and conditions, contact your local Contractor or go to Rheem.com for a copy of the product warranty certificate.
    2Based on Internal R&D Testing, May 2022. Sound levels are also dependent on proper installation and location of outdoor product.
    3Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR. Ask your contractor for details or visit EnergyStar.gov.
    4Factory or field installed in the furnace coil or air handler and is applicable to the complete heating and cooling system featuring Low GWP Refrigerant (A2L).

©Rheem Manufacturing Company. Rheem trademarks owned by Rheem Manufacturing Company.