Rheem Logo Background

CAD/BIM

Unit of Measure

Type

N/A Heat Pump

Nominal Capacity

N/A 48000 Btu14.07 kW4 TR

Refrigerant Type

N/A R-454B

Refrigerant Furnished oz.

N/A 103

Compressor Type

N/A Scroll

Sound Level

N/A 71 dB

Weight

N/A 244 lb

Voltage

N/A 208 to 230 V

Number of Phases

N/A 1

Frequency

N/A 60 Hz

Maximum Overcurrent Protection

N/A 50 A

Minimum Circuit Ampacity

N/A 30 A

Compressor - Rated Load Amps

N/A 22.4 A

Compressor - Locked Rotor Amps

N/A 126 A

Condenser Fan Motor - Full Load Amps

N/A 1.0 A

Condenser Fan Motor - Locked Rotor Amps

N/A 2.40 A

Net Face Area - Outer Coil

N/A 23.5 ft²

Tube Diameter

N/A 0.276 in

Number of Rows

N/A 1

Fins per Inch

N/A 24

Outdoor Fan Diameter

N/A 26 in

Number of Blades

N/A 3

Motor HP

N/A 1/5 hp

CFM

N/A 4264 ft³/min

RPM

N/A 850

Watts

N/A 203 W

Air Handler

N/A RCFY4821STAN

Total Capacity

N/A 45500 Btu13.3 kW

Net Sensible Capacity

N/A 34900 Btu10.2 kW

Net Latent Capacity

N/A 10600 Btu3.1 kW

SEER2

N/A 13.4

EER2

N/A 9.0

Indoor CFM

N/A 1425 ft³/min672.5 L/s

Depth

N/A 35 3/4 in908 mm

Width

N/A 35 3/4 in908 mm

Height

N/A 39 in991 mm

Shipping Depth

N/A 38.38 in975 mm

Liquid Line O.D.

N/A 3/8 in

Suction Line O.D.

N/A 7/8 in

N/A

  • 7mm Condenser Copper Coil: Requires less refrigerant allowing for a smaller and lighter footprint while enhancing reliability
  • PlusOne® Expanded Valve Space: 3 in. – 4 in. – 5 in. service valve space – provides a minimum working area of 27-square inches for easier access
  • PlusOne® Triple Service Access: 15 in. wide, industry leading corner service access, two fastener, removeable corner and individual louver panels – makes repairs easier and faster
  • Designing for Sustainability with Low GWP: For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems. This new requirement will result in a 78%2 lower GWP than previous-generation refrigerants — with only minimal changes to system installation. For us, this is another step toward our continued sustainability goal of reducing greenhouse gas emissions, while still delivering an exceptional level of energy efficient, dependable comfort
  • PlusOne® Refrigerant Detection System™3: An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation — if excess refrigerant is detected

©Rheem Manufacturing Company. Rheem trademarks owned by Rheem Manufacturing Company.